Coriolis mass flowmeter
CoriolisMaster FCB430 and FCB450
With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.
Overview
With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.
The FCB400 series delivers:
Up to five modular I/Os
– Multivariable meter design
– Optional plug-in cards
– Automatic firmware update
SmartSensor
– All digital solution
– Installation flexibility
– Meter intelligence located in the sensor
SensorApplicationMemory
– Maximum data security
– Plug and play electronics replacement
ABB common look and feel
– Easy Set-up
– Operation through the glass via capacitive keys
VeriMass on-board verification and diagnostics
– Online preventive maintenance
– Extended maintenance cycles
– Reduced maintenance effort
Designed for 70 °C (158 °F) ambient temperature and high vibrations
Lower pressure drop
Self-draining
Global approvals for explosion protection
The FCB450 adds:
DensiMass software for direct concentration measurement
FillMass software for filling application control
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCB450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB430
– -50 to 160 °C (-58 to 320 °F)
FCB450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1 - Power supply
– 11 to 30 V DC, 110/230 V AC
Fieldbus & HART
The version matrix document shows for each protocol the software revision that’s compatible to the hardware and firmware revision of the device.
- Read first
– Software/hardware revisions: Version matrix
Software and documentation:
- HART
– Software: DTM, EDD
– Driver description: Supplementary information
Stand-alone tool:
ABB offers software tools that use the listed drivers above for your device configuration and monitoring requirements. Read more & download
Fieldbus solutions:
ABB offers a wide range of fieldbus products, accessories, tools, support documentation, applications and news. Read more